logotitle

 P20功率输出开关压电阀--Hoerbiger.com



P20 contains P9 valve,micro filter, pressure regulator and pneumatic amplifier.
p20-2
P10-1

 



Versions
  • normally closed (NC)
Note:

The valve for the P20-OEM series fulfils the requirements for approval as an intrinsically safe device when used with an appropriate controller.
Characteristics Symbol Unit Description
General Features
System     Poppet valve system,pneumatic pilot
control with piezo valve, some overlap
Mounting     Flange (see dim.drawing)
Pipe Connection     Flange
Port size     NW_2
Weight (mass)   kg 0.100
Flow direction     On: from 1 to 2
Off: from 2 to 3 (*
Installation position     Optional
Medium and ambient
temperature range
Vmin. /max. °C
 
-10 to +60
Note: Contact technical department advice if used in temperatures between -30 to +80°C
- dewpoint 10K under ambient temperature
Medium     Dry or filtered air (30μ) , no or minial oil
mist lubrication (max. 30mg/m^3)
Pneumatic Characteristics
Nominal pressure Pmin./max. bar 6
Operating pressure Pmin./max. bar 1.5 - 8
Nominal flow@20℃ QN l/min 130 (from 6 to 5 bar)
Nominal size   mm 2.0
Electrical Characteristics
Nominal voltage UN V +/- 24 DC
*control advice to be considered
Capacity C nF < 100
Switching energy E mWS 0.029
Holding energy P W 0
Connection     Cable 300 mm long
Switching time@20℃ tON
tOFF

ms
ms

< 20 (10% of discharge pressure)
< 20 (90% of discharge pressure)
Electrical protection   IP 20
(* outlet air not included (ported)
3/2 Way Piezo Valves NW 2- Series P20-OEM
Version
 
Symbol
 
Order Instructions
Type Order No.
Pilot valve,
normally closed
type1 P20 381RF-NG-COEM PS10021-001A
Base plate     PS10531-A-01

Type: P20 381RF-NO-COEM

P20 381RF-NO-COEM

版权所有 南京易捷自动测试技术有限责任公司
电话:025-85406076/85407644    传真:025-85407644    E-mail:sales@njetc.com service@njetc.com
地址:江苏省南京市中央路399号天正国际广场14E    邮编:210037